MIL-DTL-3661/40B
REQUIREMENTS:
1. Design and construction. See figure one.
2. Dielectric withstanding voltage: Sea level 500 Volts r.m.s. at 60Hz.
3. Bushing torque: 8 pound-inches.
4. Lamp (non-replaceable): MIL-DTL-6363/5 "Part number M6363/5-1AS15"
5. Shock: Method II
6. Wire leads shall be in accordance with SAE-AS22759/11.
7. Threaded stud case shall be fabricated from a corrosion-resistant steel. The finish is
optional.
8. Weight: 0.005 pound maximum.
9. Marking: Type designation to be stamped on the wire or insulating sleeve.
10. If Electromagnetic Interference (EMI) shielded; case must be grounded.
TABLE I. Conformance Inspection.
Type Designation
Tests MIL-DTL-3661
Extent of Approval
LHC82 / 1YT2
(12 Sample units)
LHC82 / 2YT2
All test of Table IV
LHC82 / 1WT2
ALL
LHC82 / 1RT2
(2 Sample units each)
LHC82 / 1GT2
Group I of Table IV
LHC82 / 1BT2
(visual and mechanical
LHC82 / 1CN2
examination only)
LHC82 / 2WT2
LHC82 / 2RT2
LHC82 / 2GT2
LHC82 / 2BT2
LHC82 / 2CN2
TABLE II. Type Designation.
2