MIL-DTL-3661D
SEE
NOTE 2
.500
Ø.125 ±.001
MIN
.015 X 45°
Ø.438
mm
INCHES
±.015
0.03
.001
5/16 - 32 NEF-2A
0.05
.002
0.38
.015
KNURL
UNDERCUT Ø.270 ±.002
0.79
.031
1.70
.067
1.98
.078
3.10
.122
3.18
.125
6.86
.270
1.500
11.13
.438
±.015
12.70
.500
.122 ±.001
38.10
.031
1.500
±.015
Ø.270 ±.002
SEE
NOTE 3
TEST PLUG MIGET-FLANGE
NOTES:
1. ALL DIMENSIONS IN INCHES.
2. THE SHANK LENGTH SHALL BE AS REQUIRED (SEE 3.2).
3. FOR INCANDESCENT A = .067 +.000
-.002
FOR NEON
A = .078 +.000
-.002
INCHES
mm
SEE 3.2
.375
.001
0.03
±.015
.010
0.25
SEE 3.2
.093
.015
0.38
.031
±.001
0.79
.055
1.40
.089
2.26
.375
.090
2.29
±.015
.091
2.31
.093
2.36
.180
4.57
.375
SEE 3.2
9.53
1.078
27.38
UNDERCUT BELOW THREAD
.125 ±.015
ROOT DIAMETER
KNURL
.125 ±.015
.055 ±.001
1.078
.090 ±.010
.180
.089
.031 ±.015
±.010
.091
NOTE: ALL DIMENSIONS IN INCHES.
TEST PLUG FOR SUBMIGET-FLANGE-BASE-INDICATOR-LIGHT HOUSINGS
FIGURE 6. Test plugs for midget and submidget-flange-base-indicator-light housings (contact-spring-pressure test).